Number 4 is a combustion vent for an appliance such as a furnace boiler water heater or.
Exhaust vent roof clearance.
Number 2 is a vent for an exhaust fan like those found in bathrooms and laundry rooms.
Direct vent exhaust clearance distances for gas fueled appliances.
An exception is made for non combustible walls such as solid masonry or concrete.
Exhaust vent clearance for all climates.
Number 3 is a vent for an attic space called a roof vent or turtle vent they release hot air from the attic.
Clearance distances are given for a gas appliance b vent at the rooftop.
Vegetation must not be allowed to grow within 3 feet of an exhaust vent.
For gas fired water heater vents.
In all areas exhaust vents should be at least 1 foot above roof surface.
The exhaust vent pipe must extend at least 12 300 mm out past the exterior wall.
This article series explains how to install bathroom exhaust fans or vents the vent ducting the vent termination at the wall soffit or roof vent fan wiring bath vent duct insulation bath vent lengths clearances routing and we answer just about any other bathroom ventilation design or installation question you may have.
14 the net free area of an air intake or exhaust outlet shall be equal to or greater than the cross sectional area of the duct served.
Gravity ventilators aura vent.
Exhaust vents must not be allowed to be obscured or hidden by vegetation.
We discuss fire safety fire clearances and other gas appliance venting details for b vent chimneys.
12 the gross area of the screens or grilles installed in intake and exhaust openings shall be three times that of the duct served.
Metal b vent chimney clearance distances above and on the roof.
Sps 323 15 note 1 these clearances apply except if the listing of an appliance specifies different clearance in which case the listed clearance takes precedence.
Gravity ventilators aura vent w curb mount flange.
Single wall vent pipes cannot pass through a ceiling floor firewall or wall.
This article series describes b vent metal chimneys used for gas fired appliances.
Ul documentation for all products.
Install a listed horizontal termination cap or if necessary install a 90 elbow and appropriate length of vertical venting.
Exhaust vents must be protected against rain and equipped with back flow prevention features e g flap dampers.
Sps 323 15 note 2 if listed type l venting system piping is used the clearance may be in accordance with the venting system listing.
They exhaust moist air to the outside.
Roof turbine versus the aura ventilator.
6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
Table illustrations of the required space between a direct or side wall vent for a gas fired heating appliance and building windows doors corners gas meter air intakes sidewalks balconies decks and other building features.